FORCED CIRCULATIONFOOD CONCENTRATION SYSTEMS

Home / Systems

MVR forced circulation evaporator system

Review mechanical vapour recompression alongside circulation power, product boiling behaviour, electrical service and start-up heating requirements.

Recompression changes the heating supply

Mechanical vapour recompression raises the useful heating condition of process vapour so it can be reused. It does not replace the circulation pump or remove the need to select the heater and separator against the product. Request the vapour and liquid circuits together.

Compare the complete electrical load

A meaningful comparison includes the recompressor, circulation pump, vacuum system and auxiliaries. Confirm the duty point and operating range rather than comparing a compressor power figure with another system's total utilities. Include start-up heating and condensate handling in the proposed scope.

Check the vapour basis

State the operating pressure, boiling-point elevation and expected vapour composition. Entrainment control and the required temperature lift affect the proposed heating arrangement. Product trials and a verified balance should support any performance guarantee.

Information to include in your enquiry

  • Electrical service and tariff basis
  • Vapour pressure and composition
  • Product boiling-point elevation
  • Start-up and part-load requirements

Equipment to review together

Circulation pump & drive functional diagram
MODULE 01

Circulation pump & drive

Keep the loop moving. The circulation pump sets the flow through the heater. That flow is distinct from the incoming feed and from the mass of water evaporated. Selection must follow the concentrated liquid throughout the planned operating range, including start-up and restart after cooling.

Review structure & specification →
Entrainment separation functional diagram
MODULE 04

Entrainment separation

Protect the recovered vapour. Droplets leaving with the vapour represent product loss and can contaminate downstream equipment. A separation device must work with the product’s foam and fouling behaviour. The choice of internals depends on the operating envelope and cleaning access.

Review structure & specification →
Controls, sampling & CIP interfaces functional diagram
MODULE 08

Controls, sampling & CIP interfaces

Observe the limits; validate the clean. A useful control philosophy connects each process risk to a measurement and response. Loss of circulation, feed interruption or a changing vacuum needs a defined action. The cleaning boundary must include the pump and every product-contact part of the loop.

Review structure & specification →